After long time,due to Busy life I was unable to write you.
in this time I am going to say about OLD great thing.
I was able to touch a Very OLD Telephone exchange called NEAX61E.
this was a great system in the history and many countries ware powered by this NEAX61E system.
it was a great creation of NEC company in JAPAN.though it is a old system I believe many 3rd world countries are using this system yet and this article will remind your memory if you have worked with this system in your life.
so I thought to put some switching commands to recall your memory.
1.Display
DSP:
2.Display system status
DSP:SOS;
3.To Reconnect
SOD:SPR,N=number; (number must without area code)
4.To Disconnect Out oing Calls
SOD:SPS,N=number,,ORG;
5.To Disconnect All Calls (TOS)
SOD:SPS,N=number,,ALL;
6.Call Baring (ALL)
SOD:CLC,N=number,,,RC=101;
7.To add IDD Facility
SOD:CLC,N=number,,,RC=000;
8.To Remove IDD Facility
SOD:CLC,N=number,,,RC=004;
9.Check The Number Details
PSD:N=number;
10.To Add New Connection
SOD:NEW,N=number,EL=xxxxxxxx,30; (EL must include 8digits)
11.Delete Numbers
SOD:DSC,N=number,EL=xxxxxxxx;
then
SOD:UAN,N=number
12.Malicious Call Trace (This is Not a CLI support system)
MTR:REG,N=number
and also there are thousands of commands are using with this system.I just wanted to recall your memory.
Subscribe to:
Post Comments (Atom)
15 comments:
My name is Adrián Córdoba, and I was working with NEAX61E, on installation test and support, for 12 years. And after that, I work with NEAX61SIGMA, for 7 years.
Those years were my hapiest season.
--
Adrián Córdoba (from Argentina)
Dear Adrián Córdoba,
I am very Happy about your post and I would like to inform you that NEAX61E & NEAX61 SIGMA is still using in Sri Lanka(My Country).I think withing two years all systems will be changed.
Thanks for your comment...
Uditha Kumara Wijesinghe
In my country (Argentina),threre are, maybe, 70 NEAX61E (hosts and remote systems) and 12 NEAX61SIGMA (hosts and remote systems), in service.
There is not date for turn them off, yet.
Those systems are the best.
With a good mantenance, you'd have switching system forever. But switching technologies became obsolete.
--
Adrián Córdoba
If you need an specialist, you know me!
In my country(Thailand) still use NEAX61E/KE more than 100 host and RSU more than 200 RSU now NEAX61Sigma 27exchanges. Now NEAX61E/KE will be change to NGN soon.
I am support NEAX61E/KE and Sigma more than 10 years. Now still working with NEC coporation(Thailand) Ltd. It good feeling you told to NEAX61 Switching network.
Regards,
Pairote@NEC-Thailand
I HAVE BEEN GOING CRAZY LOOKING FOR ASSISTANCE WITH THE COMMANDS FOR THE NEAX 61E. I HAVE BEEN ASSIGNED TO AN EXCHANGE THAT RUNS ON THIS SWITCH AND I HAVE BEEN HAVING DIFFICULTY GETTING THE COMMANDS. I FOUND YOU THROUGH GOOGLE . CAN YOU ASSIST ME WITH THIS ???
Hi to all, Is any one here know the command EXM for NEAX61E? I really need syntax for this command. Hope you can help me.
Is any one here know the command EXM for NEAX61E? I really need the syntax of this command. Hope you can help me.
Any one know the command EXM for NEAX61E?
Hi, Does anyone know of some NEAX61's being taken out as I wish to get hold of some spares.
Thanks
Chris
chris_s_joel@hotmail.com
Lol! I worked on Neax61 switches more than 10 years ago and yes they are very good! I did installation and testing from start in Philippines and a project with Siguma (as Japanese pronounce Lol) I had in Sri Lanka.
How about
dsp:lrf
view all
view anwd
view swptn
I even heard in NZ they still have the 61k until last decade maybe.
Be careful with master console! But phase restarts are the exciting part
i am from iran.
and i have a link to download last version of GUI. can you help me?
i think last version of GUI is GUI79.
but my system have GUI57.
please help me to download last version of GUI
does any one know mean of ODC-Err 104 and also the solution ? i found this error while performing command >odc:reg; in Neax 61E Msc .
As for New Zealand, NEAX 61K and 61S are still in service. Slowly being replaced with 61E RLUs, but very slowly. These switches have been in service here since early 1980s and still going strong. How about that!
I have been assigned for a project which involves decoding CDR's from NEC Neax 61E switch. I am searching for the CDR specification document could any experts on this switch help me out with CDR specification document. I would appreciate the help.
You can contact me on laiju1982@gmail.com
Thanks
Laiju Joseph
Hi I am from India, I am involved in a mediation project where we have to normalize NEC Neax 61E CDRs. For this i am not able to get the CDR specification document. If any off you guys have the CDR specification document for NEC Neax 61E switch please send it to me it will be very very helpful.
you can mail be at laiju1982@gmail.com
Thanks
Laiju Joseph